2,746 research outputs found

    The MRPC-based ALICE Time-Of-Flight detector: status and performance

    Full text link
    The large Time-Of-Flight (TOF) array is one of the main detectors devoted to charged hadron identification in the mid-rapidity region of the ALICE experiment at the LHC. It allows separation among pions, kaons and protons up to a few GeV/c, covering the full azimuthal angle and -0.9 < eta < 0.9. The TOF exploits the innovative MRPC technology capable of an intrinsic time resolution better than 50 ps with an efficiency close to 100% and a large operational plateau; the full array consists of 1593 MRPCs covering a cylindrical surface of 141 m2. The TOF detector has been efficiently taking data since the first pp collisions recorded in ALICE in December 2009. In this report, the status of the TOF detector and the performance achieved for both pp and Pb--Pb collisions are described.Comment: 4 pages, 6 figure

    Long-term operation of a multi-channel cosmic muon system based on scintillation counters with MRS APD light readout

    Get PDF
    A Cosmic Ray Test Facility (CRTF) is the first large-scale implementation of a scintillation triggering system based on a new scintillation technique known as START. In START, the scintillation light is collected and transported by WLS optical fibers, while light detection is performed by pairs of avalanche photodiodes with the Metal-Resistor-Semiconductor structure operated in the Geiger mode (MRS APD). START delivers 100% efficiency of cosmic muon detection, while its intrinsic noise level is less than 10^{-2} Hz. CRTF, consisting of 160 START channels, has been continuously operated by the ALICE TOF collaboration for more than 25 000 hours, and has demonstrated a high level of stability. Fewer than 10% of MRS APDs had to be replaced during this period.Comment: Proceedings of NDIP-2008. 8 pages, 8 figures, 6 reference

    RPC with low-resistive phosphate glass electrodes as a candidate for the CBM TOF

    Get PDF
    Usage of electrodes made of glass with low bulk resistivity seems to be a promising way to adapt the Resistive Plate Chambers (RPC) to the high-rate environment of the upcoming CBM experiment. A pilot four-gap RPC sample with electrodes made of phosphate glass, which has bulk resistivity in the order of 10^10 Ohm cm, has been studied with MIP beam for TOF applications. The tests have yielded satisfactory results: the efficiency remains above 95% and the time resolution stays within 120 ps up to the particle rate of 18 kHz/cm2. The increase in rate from 2.25 to 18 kHz/cm2 leads to an increase of estimated "tails" fraction in the time spectrum from 1.5% to 4%.Comment: 8 pages, 6 figures, submitted to Elsevier Scienc

    Scintillation counter with MRS APD light readout

    Full text link
    START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.Comment: 6 pages, 5 figure

    Perspectives for Positron Emission Tomography with RPCs

    Get PDF
    In this study we address the feasibility and main properties of a positron emission tomograph (PET) based on RPCs. The concept, making use of the converter-plate principle, takes advantage of the intrinsic layered structure of RPCs and its simple and economic construction. The extremely good time and position resolutions of RPCs also allow the TOF-PET imaging technique to be considered. Monte-Carlo simulations, supported by experimental data, are presented and the main advantages and drawbacks for applications of potential interest are discussed.Comment: Presented at "RPC2001-VI Workshop on Resistive Plate Chambers and Related Detectors", Coimbra, Portugal, 26-27 November 2001 (5 pages

    Subthreshold and near-threshold kaon and antikaon production in proton-nucleus reactions

    Full text link
    The differential production cross sections of K^+ and K^- mesons have been measured at the ITEP proton synchrotron in p+Be, p+Cu collisions under lab angle of 10.5^0, respectively, at 1.7 and 2.25, 2.4 GeV beam energies. A detailed comparison of these data with the results of calculations within an appropriate folding model for incoherent primary proton-nucleon, secondary pion-nucleon kaon and antikaon production processes and processes associated with the creation of antikaons via the decay of intermediate phi mesons is given. We show that the strangeness exchange process YN->NNK^- gives a small contribution to the antikaon yield in the kinematics of the performed experiment. We argue that in the case when antikaon production processes are dominated by the channels with KK^- in the final state, the cross sections of the corresponding reactions are weakly influenced by the in-medium kaon and antikaon mean fields.Comment: 24 pages. accepted for publication at J.Phys.
    • …
    corecore